Multi-Gas Monitor
|
Model GX-2009  |
| Approvals: ATEX, JML, IECE, CE, CSA |
| Features: |
- Simultaneous and real-time detection of 4 gases LEL, 02, H2S & CO
- Large simultaneous display for 4 gases
- Water and dust resistant, IP67
- Loud alarm buzzer 95dB at 30cm.
-
3 bright LED alarm windows
- Recargeable Ni-MH battery pack
- Continuous operation for up to 20 hours
- Built in shock-resistant coating
- RFI shielded housing
- Vibration alarm
- Datalogging standard
- Auto-calibration
- STEL and TWA readouts
- Peak hold readout
- Continuously displays current time
|

|
|
Model GX-2001  |
| Model RP-6 Sample-draw pump for Model GX-2001 |
| Approvals: CSA/ATEX, PTB/ATEX, JML, KOSHA, CE, MED |
| Features: |
- Four gas simultaneous detection of HC, O2, H2S and CO
- Smallest four gas monitor in the market
- Vibration alarm
- Alarm trend data
- Datalogging standard
- Auto-calibration
- Ni-Cad rechargeable battery
- Continuously operates for over 10hrs
- Large LCD display with back-light
- High impact, RFI shielded structure
- Display real time
- Peakhold, STEL and TWA readouts
- Intrinsically safe
- Attachable sample drawing pump available
|
| Speciftcations subjest to change without notice. |
 |
Model GX-2003 (Type A)  |
| Approvals: CSA, JML |
| Features: |
- Compact size weights only 11 ounces
- Monitors combustibles, O2, CO, and H2S
- 0 to 100%vol methane version available
- Autoranging display of %vol and %LEL
- Internal sample drawing pump
- Vibration, visaul, audible alarm types
- Automatic backlight during alarms
- Cailbration reminder and lock out
- Battery pack direct charges in the instrument or separate from unit
- Alarm latching or non-latching
- Up to 600hrs of datalogging with alarm tends
- Autocalibration or single calibration
- Alarm silence capable
- Fast charge in just 90 minutes
|
 
|
|
Model SM 2000U |
| Features: |
- Stand alone system, no PC needed for operation
- Calibrate, bump test, charge, and archive data
- Software manages records by serial #, user ID, or station ID
- Each station is equipped with configuration control and status indicators
- User adjustable test times and tolerances
- Automatic quick charge of instrument in 90 minutes or less
- Alkaline recognition – will not attempt to charge alkaline batteries (SM-2003U)
- Exhaust line connection for test gas venting
- Records are stored as a tab delineated text file (.txt format can be imported into a spreadsheet)
- Software is Windows 2000, and XP compatible
- Operates on any Pentium II or higher PC
- USB port for downloading data to a USB flash drive
- USB flash drive included
|
| Speciftcations subjest to change without notice. |
 
|
|
Docking and Calibration Station |
| Features: |
- Automated instrument management for the GX-2001 and GX-2003
- Simultaneously service up to 10 instruments
- Calibrations, bump tests, and data downloads automatically performed and archived
- Manage instruments and archive records by serial #, user ID, or station ID
- Services are automatic, on-demand, or custom intervals
- Each docking module equipped with built-in flow control and status indicators
- Approaching and past due service prompts
- Alkaline recognition
- Single exhaust line for all instruments
- 5 inlet ports for separate gas mixtures
- Automatic quick charge in 90 minutes or less
- Create and save a list of common gas mixtures
- Automatic tracking of cylinder expiration
- Save factory and user default configurations for uploading to instruments
- Password protect configuration controls
- Records are easily exportable as CSV data
- Software is Windows 98, NT, 2000, and XP compatible
- Operates on any Pentium II or higher PC
|
| Speciftcations subjest to change without notice. |
 |
Model EAGLE 1 to 6 gas portable multipurpose monitors  |
|
| Approvals: CSA & UL |
|
| Features: |
|
- Simultaneously readout of up to 6 different gases
- Wide variety of field proven gas sensor available
- PPM/LEL hydrocarbon detection
- Low flow pump shut off and alarm
- Methane elimination switch for environmental use
- 30 hours of continuous operating
|
| Specifications: |
| Detection principle |
Catalytic combustion |
Galvanic cell |
Electrochemical cell |
| Measuring gas |
Combustibles |
O2 |
H2S |
CO |
| Measuring range |
0-100%LEL
0-50,000ppm (CH4)
0-11,000ppm (HC) |
0-40vol% |
0-100ppm |
0-500ppm |
| Alarm preset point |
30/50%LEL |
18.0/25.0vol% |
10/30ppm |
50/100ppm |
| Operating temp |
-10C~+40C, below 95%RH, non-condensing |
| Power source |
Alkaline batteryX4pcs, 16hrs minimum |
| Dimensions & weight |
Approx. 150(W)X274(H)X178(D)mm, 2.8kg |
| Specifications subject to change without notice. |
 |
Model EAGLE 2 1 to 6 gas portable multipurpose monitors  |
|
| Approvals: CSA & UL |
|
| |
|
 |
| |
| Specifications subject to change without notice. |
|
|
Model GX-3000  |
Features: |
- Hand-free monitor for HC % temp.
- 360 degree visual/ adible & low batt alarm
- Rechargeable battery up to 12hrs minimum
- Back-lit for LCD display and internal data logging (up to 180 days)
|
| Specifications: |
Detection principle |
Catalytic combustion |
Measuring gas |
HC or CH4 (specify when ordering in air |
Measuring range |
0-100%LEL |
Alarm preset point |
1st: 10%LEL
2nd: 50%LEL |
Sampling method |
Diffusion sampling |
Operating temp |
-20C~+40C, 30-95%RH, non-condensing |
Power source |
Ni-Cd battery recharged by AC220V charger |
Dimensions & Weight |
Approx. 152(W)56(H)56(D)mm, Approx. 500g |
| Specification subject to change without notice. |
Single Gas Monitor
|
|
Model GP-88A (LEL version)  |
Model GP-88AS (PPM version)  |
| Approvals: CSA, JML |
| Features: |
- Dual expanded scale with automatic suction
- Meter illuminated in dark places
- Peak hold function & earphone jack provided
- Low battery alarm
|
| Specifications: |
| |
| Specification subject to change without notice. |
|
|
Model GP-226 Intrinsically Safe in Japan  |
| Approvals: H.K, JML |
| Features: |
- Dual expanded scale with automatic suction
- Simple design with small size & light weight
- Large size analog meter
|
| Specifications: |
| Detection principle |
Catalytic combustion |
| Measuring gas |
Combustible gas (iso-butane or CH4 cal) in air |
| Measuring range |
0-20%LEL & 0-100%LEL (change-over) |
| Sampling method |
Internal Pump suction |
| Alarm preset point |
20%LEL |
| Operating temp |
-10C~+40C |
| Batteries & Operating hrs |
internal Ni-Cad battery, 4 hrs minimum |
| Dimension & weight |
Approx. 150(W)X85(H)X 125(D)mm, Approx. 1.6g |
| Specification subject to change without notice. |
|
Model SP-210 (Natural gas and town gas)  |
Model SP-210L (LPG)  |
| Approvals: JML, Intrinscally safe Exiad II BT3 in Japan |
| Features: |
- LED bar of gas concentration
- Flow check function
- Visual/ Audible/ Vibration alarm
- Flexible tapered nozzle for pipes and fittings
- Easy to replace, long lasting sensor
- Water resistant sealed housing
- Compact and lightweight
|
| Specifications: |
| Model |
SP-210 |
SP-210L |
| Gas detected |
Natural gas & town gas in air |
LPG in air |
| Detection principle |
Special catalytic/ semiconductor combination sensor, with automatic sampling (pump drawn) |
| Leak detectabillty range |
10~10000ppm |
| Display |
LED |
| Alarm functions |
Zero error, Low flow rate, Low battery voltage (All LED's blink.) |
| Explosion proof |
Intrinscally safe design (Exiad II BT3) in Japan |
| Power source |
AA size batteries (3 pieces) |
| Continuous Operation Time |
Approx. 8 hours with Alkaline batteries |
| Ambient temp. |
-20C~+50C |
| Dimension |
Approx. 36(W)X128(H)X57(D)mm (1.37"(W)X5.0"(H)X2.2"(D) |
| Weight |
Approx. 320g (11.2oz) |
| Specifications subject to change without notice. |
|
Model NP-237H  |
|
| Approvals: KIMM, MED, JML |
| Features: |
- LEL to 100% by vol with 4 range change-over switch
- Two version either for land use or marine use
- Suited for detection of HC gas/ Vapours in an inert gas
|
| Specifications: |
| Detection principle |
Catalytic combustion, thermal conductivity |
| Measuring gas |
Combustible gas (LPG, Gasoline & LEL scale) |
| Measuring range |
0-10/10-100%LEL & 0-20/0-100vol% |
| Operating temp. |
-10C~+40C |
| Functions |
Peak hold, Back light |
| Batteries & Operating hrs |
Alkaline batteriesX4pcs, 7hrs minimum |
| Dimension & weight |
Approx. 160(W)X90(H)X150(D)mm, Approx. 2.7g |
| Specifications subject to change without notice. |
|
Model GH-202F  |
| Features: |
- High visibility level meter and buzzer sound
- Automatic balance circuit against background level
- Automatic suction
- Fumigation application
|
| Specifications: |
| Detection principle |
Semiconductor method |
| Detectable gas |
LPG, city gas, methyl bromide, freon, ammonia etc. in air |
| Minimum detectability |
High range: 20ppm (in case of freon 30ppm) Low range: 200ppm |
| Sampling method |
Suction fan |
| Operating temp. |
-5C~+40C |
| Power source |
Alkaline battery X 6pcs, 4hrs minimum by Alkaline battery |
| Dimension & weight |
Approx. 50(W)X270(H)X60(D)mm, Approx. 450g |
| Specifications subject to change without notice. |
Oxygen monitors
|
Model OX-07  |
| Approvals: ATEX, JML, IECE |
| Features: |
- Intrinsically safe ExiallCT3
- Extension cable available (5m standard, 10m, 20m and 30m)
- Maximum 5000 hrs of continuous operation by 2 'AA' alkaline dry cells
- Impact resistant protective rubber boot
- Large LCD display with auto backlight
- Audible/ Visual/ Vibration alarms
- Compact and light weight
- 66W X 114H X 33D mm, 230g only
|
| Specifications: |
| Type |
Type A |
Type B |
| Gas detected |
Oxygen (O2) in air |
| Detection range (Increments) |
0.0-40.0%vol. (0.1%vol) |
| Alarm set point |
Low: 19.5%vol, High: 23.5%vol, Over: 40%vol |
No Alarm |
| Trouble alarm |
Sensor disconnection, low battery, circuit failure, cailbration range error |
| Alarm types |
Gas alarm: flashing light, intermittent buzzer and flashing gas value, pushing vibration |
No Alarm |
| Trouble alarm: flashing light, intermittent buzzer and Display of error message |
| Continuous operation |
Maximum 5000 hours (at 25C, no alarm, no back light) |
| Operating temp. & humidity |
-20C~+50C: Humidity below 95%RH (non-condensing) |
| Special functions |
Manual backlight for LCD (automatically lit during alarm) Peak hold (maximum and Minimim) |
| Dimensions & weight |
Approx. 66(W) X 114(H) X 33(D)mm Approx. 230g (Instrument only) |
| Standard accessories |
Hand strap |
| Optional accessories |
Extension cable 5m, 10m, 20m, 30, carrying case |
| Specifications subject to change without notice. |
|
|
Model OX-01 |
| Approvals: CSA, PTB/ATEX, JML |
Specifications: |
| Detection principle |
Galvanic Cell |
| Measuring Gas |
Oxygen (O2) in air |
| Measuring range |
0-10%vol (0.1%/ digital) |
| Alarm preset point |
Low: 19.5%vol, High: 23.5%vol, Over: 40%vol |
| Sampling method |
Diffusion sampling |
| Operating temp |
-20C~+50C, below 90%RH, non-condensing |
| Power source |
Alkaline battery AAA sizeX2pcs |
| Dimensions & Weight |
Approx. 35(W)X105(H)X20(D)mm, Approx. 100g |
| Specifications subject to change without notice. |
 |
Model GW-2X  |
| Approvals: CSA, PTB/ATEX, JML, KOSHA, CE, CCS |
| Specifications: |
| Detection principle |
Galvanic cell |
| Measuring gas |
Oxygen (O2) in air |
| Measuring range(increments) |
0-40% vol (0.1%/digit) |
| Sampling method |
Diffusion sampling |
| Preset alarms (Adjustable) |
Low: 19.5%vol, High: 23.5%vol, Over: 40%vol |
| Gas sampling |
Diffusion sampling |
| Power source |
One coin type Lithium battery (CR 2450) |
| Operating temp & humidity |
-10C~+40C, below 85%RH, non-condensing |
| Dimensions & weight |
Approx. 64(W)X43(H)X23(D)mm, Approx. 60g |
| Specifications subject to change without notice. |
Infrared Gas Monitors
 |
Model RI-415  |
|
| Approvals: H.K, JML |
| Features: |
- Available to measure from high concentration(vol%) to lower concentretion (%LEL)
- Explosion proof (Detector: Explosion proof, other electrical circuit & pump-intrinscally safe design)
- Available to measure HC or CH4 in N2 or inert gas using a reliable NDIR detector
|
 |
Model RX-415  |
|
| Approvals: H.K, JML |
| Features: |
- Available to measure from high concentration(vol%) to lower concentretion (%LEL)
- Explosion proof (Detector: Explosion proof, other electrical circuit & pump-intrinscally safe design)
- Available to measure HC/O2 or CH4/O2 in N2 or inert gas and air with a reliable NDIR method
|
| Applications: |
- Measures gas concentrations in tank of LNG and LPG carriers.
- Measures gas concentrations in crude oil tankers
- Measures gas concentration in inert gas generating system (IGS)
|
 |
Model RX-515  |
|
Model RX-516  |
Model RX-517  |
| Approvals: Baseefa/ATEX, MED, H.K, JML |
Features:
- Dual range detection of CH4 or HC in %vol and %LEL
- Unique gas combinations include: CH4/ O2/ CO/ CO2/ HC/ O2/ H2S
- Accurately measure CH4 or HC from inerted tanks with infrared sensor
- High range H2S 0-1,000ppm available (RX-517)
- Intrinsically safe design
- Datalogging (Max 30 hours of interval trend)
|
- Model RX-515: LNG carrier
Ch4: 0-100%LEL to 100%vol
O2: 0-25%vol
CO: 0-1,000ppm
CO2: 0-20%vol
- Model RX-516: Crude oil tanker
HC: 0-100%LEL to 100%vol
O2: 0-25%vol
H2S: 0-100.0ppm
- Model RX-517: Crude oil tanker
HC: 0-100%LEL to 100%vol
O2: 0-25%vol
H2S: 0-100.0ppm and 0-1,000ppm
|
 |
Model RI-85 CO2 monitor  |
|
| Features: |
- Microprocessor controlled
- Internal sample-drawing pump
- LCD display with back light
- Compact and lightweight
- Audible and visual alarms
- Instaneous, Peak and Average values provided
- Recorder output signal (0-1 V linear)
|
| Specifications: |
| Detection principle |
NDIR (Non-Dispersive infrared) |
| Measuring gas |
Carbon dioxide (CO2) in air |
| Measuring range |
0-10,000ppm or 0-5%vol (Specify one range when ordering) |
| Sampling method |
Internal pump suction |
| Alarm display |
Audible and visual alarms |
| Amibent Temp. & Humidity |
-10~+40C, below 90%RH, non-condensing |
| Continuous operation |
Approx. 12hrs (Alkaline batteries, no illumination) |
| Average value time |
Selected from 1min, 3min or 15min |
| Dimensions & Weight |
Approx. 85(W)X190(H)X40(D)mm, Approx. 500g |
| Specifications subject to change without notice. |
 |
Model RI-413A  |
|
| Portable halocarbon indicator with digital readout and audible alarm |
| Features: |
- Digital display
- Microprocessor controlled
- Measurement of instaneous concentration for 7 kinds of halogenated carbon gas
- Measurement of average concentration "over" 1,3 or 15 mins
- Adjustable alarm point at 0~full scale
- Audible alarm optional
- Illuminated display
- Battery powered
- Lightweight
- Full portable
|
 |
Model RI-557  |
| Features: |
- Large LED digital read-out
- Compact and light weight (Approx. 6kg)
- Dual range standard
- Auto-sampling internal pump
- Rugged design
- Simple to operate
- Recorder output (4-20mA)
|
| Specifications: |
| Detection principle |
Non-Dispersive Infrared Absorption (NDIR) |
| Gas and range |
Specify one gas and range from list when ordering |
| Output |
Current output: 4-20mA (standard)
Voltage output: 0-1V(option) |
| Operating temp. & humidity |
0C~+40C, below 90%RH, non-condensing |
| Power source |
AC220V (or AC100V) + 10% 50/60Hz 25VA max |
| Dimensions & Weight |
Approx. 220(W)X200(H)X320(D)mm, Approx. 6kg |
| Specifications subject to change without notice. |
Toxic gas monitors
|
Model SC-01 (NH3, CL2, SO2, PH3)  |
| Approvals: CSA |
| Features: |
- Smart interchangeable sensors
- Unique extender cable for remote monitoring
- Compact (2.5X5.2X1.2 in.)
- Lightweight, 7.6 ounces
- 250 hours of continuous operation
- Operates on 2 "AA" alkaline batteries
- Audible/ Visual/ Vibration alarms
- Datalogging standard
- Impact resistant protective rubber boot
- Intrinsically safe, CSA, C/US pending
|
 |
Model SC-90 Single Gas Monitor  |
| Approvals: CE |
Features: |
- LCD digital readout
- Audible/ Visual alarms
- Sampling drawing system
- Self-diagnostic functions
- Peak hold and average reading
- Automatic backlight in the dark places
|
Specifications: |
| Detection principle |
Electrochemical cell |
| Detection gas and range |
Contact us for the list for gas range |
| Display |
Contniuous gas reading, average/peak reading and status |
| Alarm |
Buzzer sound and red LED flashing |
| Operating conditions |
-10~+40C, 30~90%RH, non-condensing |
| Power source |
Alkaline, size "C" (standard) X 4pcs: Approx. 20hrs
Ni-Cd batteries (option) X 4pcs: Approx. 10hrs |
| Dimensions & Weight |
Approx. 220(W)X80(H)X142(D)mm, Approx. 1.9kg |
Specifications subject to change without notice. |
 |
Model SP-205ACS Leak Tester  |
Approvals: CE |
Features: |
- Ideal for trace gas leak check
- Compact, light weight
- Notify by intermittent buzzer and LED light according to detection level
|
Specifications: |
| Detection principle |
Catalytic/semiconductor combination Sample-drawing with built-in pump |
| Detection gas |
Phosphine (PH3) |
Arsine (AsH3) |
Diborane (B2H6) |
Silane (SiH4) |
Hydrogen (H2) |
| Detection concentration |
0.3ppm |
0.2ppm |
0.1ppm |
0.5ppm |
1.0ppm |
| Alarm indication |
Intermittent buzzer and LED light |
| Power source |
Size "AA" Alkaline battery x 4pcs
Continuous operating time approx. 7hrs at 20C |
| Operating temperature |
0~40C |
| Dimensions & Weight |
Approx. 68(W)X155(H)X32(D)mm, Approx. 400g |
Specifications subject to change without notice. |
 |
Model FP-30  |
| Features: |
- Easy to read LCD display
- Self-diagnosis
- No warm up time
- Datalogging stores up to 99 readings and available download to PC
- Resolution 0.005ppm (FP-30)
|
| Specifications: |
| Detection principle |
Photoelectric photometry method |
| Detection method |
Colorimetric tablet method |
| Measuring gas |
Formaldehyde (HCHO) in air |
| Measuring range |
0-0.4 ppm |
0-1.0 ppm |
| Detection time |
30 min |
15 min |
| Display |
Digital LCD |
| Sampling method |
Sampling method with build-in pump |
| Operating temp |
5C~+35C, below 90%RH, non-condensing |
| Power source |
Alkaline Battery AA size X 4pcs |
| Dimensions & weight |
Approx. 85(W)X190(H)X40(D)mm, Approx. 500g |
| Specifications subject to change without notice. |
| For other gases not listed above, contact us. |
 |
Model EC-777  |
Model EC-777DG (for NF3)  |
Features: |
- Easy transportability
- Digital display(LED) for gas concentration readout
- Calibration and other sensor information stored in sensor memory
- Trend graph for alarm evidence
- Self-diagnostic functions by microprocessor
- Easy replacement of pump and sensor (less than one minute)
- Two alarm levels, trouble alarm, plus relay outputs
- Maintenance capability by remote PC
|
Specifications: |
| Model |
EC-777
|
EC-777DG |
| Detection principle |
Electrochemical cell |
Pyrolysis-electrochemical cell |
| Target gas and detection range |
Same as for GD-K71D (refer to the detectable gas list) |
NF3 in air, 0~30ppm |
| Gas concentration Display |
4 digits LED, 7 segments |
| Outputs |
Both 4~20mADC (max. loop load 300omega) and 0~10mVDC |
| Alarm display |
1st alarm: Yellow LED light, 2nd alarm: Red LED light, Trouble alarm: Green LED flashing |
| Alarm relays |
Form "C" for each alarm |
| Self-diagnostic function |
Low flow, system trouble, sensor disconnection |
| Operating conditions |
0~40C, 30~85%RH, non-condensing |
0~40C, 45~75%RH, non-condensing |
| Power requirement |
100VAC, 115VAC or 220VAC +10% |
| Power consumption |
Approx. 15VA |
Approx. 100VA |
| Applicable tubing for outer connection |
O.D. 6-1t PTFE tubing (Provided with P.P coupling) |
| Dimensions & Weight |
Approx. 150(W)X225(H)X250(D)mm, Approx. 7kg |
Approx. 150(W)X225(H)X250(D)mm, Approx. 8kg |
Specifications subject to change without notice. |
Optical Gas Indicator
 |
Model FI-21  |
| Approvals: CE |
| Features: |
- Capable of measurement for up to 8 kinds of gases
- Gas can be selected with key operation
- Direct digital readout
- Built-in sampling pump
- High accurate measurement with CCD and Fourier analysis
- Datalogging stores up to 100 readings
- Few consumable parts save maintenance cost
- Fumigation applications (Type-03)
|
| Spacifications: |
| Model |
FI-21 |
| Detection principle |
Optical interferometric method |
| Display |
Digital display (measuring gas, base gas, gas concentration, time, etc) |
| Structure |
Non-explosion proof |
| Measuring method |
Batch measurement |
| Gas sampling method |
Suction by internal pump (Pump stops operation while reading) |
| Outputs |
Data logger, 0-1VDC |
| Datalogging function |
Day, time(24hrs) and measurement results Maximum recording: 100 data points |
| Operating temp. & humidity |
5-35C, below 80%RH, non-condensing |
| Operating pressure |
Atmospheric pressure |
| Power source |
C Size alkaline batteries(4pcs) |
| Battery life |
Approx. 20hrs (without sampling) |
| Dimensions & Weight |
Approx. 200(W)X80(H)X145(D)mm, 2kg |
| Standard accessories |
Carrying case, absorption tube, sampling hose, C size alkaline batteries (4pcs), sampling "T" piece (For anaesthetic application only) |
| Optional accessories |
AC adaptor, data logger software, cable for data logger |
| Specifications subject to change without notice. |
Approvals:
|
Portable Gas Detectors
R K INSTRUMENTS (S) PTE LTD
102F, #03-10, Citilink Warehouse Complex,
Pasir Panjang Road, S (118530)
Tel : (65) 62753398
Fax : (65) 62753387
|