Single Channel

image of GP-146 to be place here

Model GP-641A
(Single -channel combustible gas detection and alarm system)
Model GD-A8
Model GP-146
Aproval: H.K, K.R, CCS
Features:
  • Compact and light weight.
  • Digital display(LED) for gas concentration readout.
  • Self-diagnostic functions by microprocessor.
  • Two alarm levels, trouble alarm
  • External output 4-20mA, Relay output
  • Maintenance mode function.
Applications:
  • LP Gas manufacturing, storage, and consuming facilities.
  • Factories using high pressure gas.
  • Chemical plants
  • General manufacturing plants.
Back to Top
Model RM-630 Series
(Single -channel gas detection and alarm system)
Features:
  • Compact and light weight.
  • Wide variety of detectable gases and detector heads
  • Two alarm levels, trouble alarm
  • Maintenance mode function.
  • Zero suppression function
  • Recorder output (option)
Applications:
  • Petro-refinery, petrochemical plants.
  • Chemical plants
  • Semiconductor manufacturing plants
  • Engineering public works
  • Power station, gas utilities
  • Iron and steel works
  • Oil/gas carriers
Back to Top
Model SD-705EC
Approvals: TIIS
Features:
  • Flame proof design
Specification:
Detection gas Hydrogen sulfide (H2S) in air
Detection principle Electro-chemical cell
Detection Range 0-30ppm
Alarm preset levels 1st: 10ppm, 2nd: 20ppm(adjustable)
Operating temp. & humidity -10C~+40C, below 95%RH (non-condensing)
External output Alarm contact: Gas alarm and trouble alarm
Single output: Gas concentration 4-20mA, Linear
Malfunction: 0.5mA
At maintenance mode & initial clear time: 2.5mA
Power source DC24V+10% (max 2.5W)
Structure Flame proof structure Exd II BT4
Signal transmission Max. 1.25km with CVVS 1.25sq cable
Max 2km with CVVS 2.0sq cable
Dimensions & Weight 205(w)X134(H)X90(D)mm, Approx. 4kg
Specifications subject to change without notice.
Back to Top

  Model SD-705RID (sample drawing type)
Model SD-705RI (Diffusion type)
Model SD-705SC-RI (Remove type)
Approvals: MED, TIIS
Features:
  • Remote detector head GD-A45RI can be installed at high location (eg. on the celling in engine room of LNG carrier and at the product facility area of FPSO and LNG RV.)
  • Optional remote calibration cap can permanently be mounted on the sensor head. Calibration work with test gas can be done on the floor with no climbing ladder.
Back to Top

  Model Tri (3)-Head Gas Detector  
For Marine Pump room
Features:
  • 3 Sensors, 1 explosion proof housing
  • Infrared sensors available for combustible gases
  • Interfaces with Beacon 410 controller
  • Available for LEL, O2, H2S and CO
  • Water repellent patented sensor coating
  • Long life sensors (2 + years typical)
Applications:
  • Wet Wells
  • Dry Wells
  • Bar Screen
  • Lift Station
  • Digesters
  • Thickeners
  • Primary Clarifiers
  • Pump Stations
  • Confined
Back to Top
Model SD-805RID Series
Features:
  • Explosion proof housing
  • IP65 ingress class
  • Small, rugged, dust and weather proof construction
  • Non-Dispersive Infrared Ray Absorption (NDIR) method capability
  • Direct digital readout
  • Back-light LCD display
  • 4-20mA linear outputs
  • Dual alarm contacts
  • Self-diagnosis by microprocessor
  • Automatic zero correction function
  • Simple adjustment with magnetic control key
Back to Top
Model M2 Series (Stand alone explosion proof transmitter)
Features:
  • Operates independent of a controller
  • Direct digital readout on backlit LCD
  • Available for LEL, H2O, CO and O2
  • 4-20mA & digital Modbus outputs standard
  • Non-intrusive calibration via magnetic wand
  • 2 fully programmable alarm relays & fail relay
  • H2 specific LEL version available
  • Infrared combustible version available
  • Patented water repellent sensor coating
  • User friendly setup push buttons & LCD menus
  • Intrinsically safe, CSA, C/US classified
Applications:
  • Petrochemical plants
  • Refineries
  • Offshore drilling platforms
  • Water & wastewater treatment plants
  • Pulp & paper mils
  • Gas, telephone, & eletirc utilities
  • Parking garages
  • Manufacturing facilities
  • Steel
  • Automotive
Back to Top
Model "S" Series (4-20mA Gas Sensor/Transmitter)
Features:
  • Explosion proof housing
  • Patented water repellent sensor coating
  • Operates independent of a controller
  • Available for LEL, H2S, CO, O2 and ppm HC
  • Long life sensors (2 + years typical)
  • Competitively priced
Applications:
  • Petrochemical plants
  • Refineries
  • Offshore drilling platforms
  • Water & wastewater treatment plants
  • Pulp & paper mils
  • Gas, telephone, & eletirc utilities
  • Parking garages
  • Manufacturing facilities
  • Steel
  • Automotive
  • Chemical storage buildings
Back to Top

Semiconductor

Model GD-K71D
Model GD-V77D
Model GD-F77D
Approvals: CE
Features:
  • High brightness LED assures clear reading even in dark places
  • Trend graph for alarm evidence
  • Self-diagnostic functions
  • Two alarm levels, trouble alarm plus relay outputs
  • Maintenance capablity by remote PC
  • Various communication networks
  • CE approved
Specifications:
Model GD-K71D GD-V77D GD-F77D
Model designation and signal transmission GD-K71D: 4-20mA
GD-K71D-NT: DC power line communication
GD-K71D-DV: Device Net
GD-K71D-LN: Lon Works
GD-V77D: 4-20mA
GD-V77D-NT: DC power line communication
GD-V77D-DV: Device Net
GD-V77D-LN: Lon Works
GD-F77D: 4-20mA
GD-F77D-NT: DC power line communication
GD-F77D-DV: Device Net
GD-F77D-LN: Lon Works
Detection principle Electronchemical cell Semiconductor method Galvanic cell
Target gas and detection range

Contact us for details

H2 in air
0~2000ppm
CH2F2(R-32) in air
0~2000ppm
O2 in air 0~25%
Gas concentration display Digital LED display, 4 digits 7 segments
Alarm display 1st alarm: Yellow LED light, 2nd alarm: Red LED light, Trouble alarm: Green LED flashing
Alarm relays Normally-open or normally-close contact for both AL1/Al2 and trouble, rated 0.25A at 125VAC/0.5 at 24VDC(Resistive load)
Self-diagnostic function Trouble, low flow, system trouble, communication error.
Operating conditions 0~40C, 30~85%RH, non-condensing 0~40C, below 90%RH, non-condensing
Power requirement 24VDC+10%. Approx.10W
Applicable tubing for outer connection O.D. 6-1t PTFE tubing (provided with P.P coupling)
Applicable cable Shielded cable, 3C, 1.25sq. (Shielded twisted one pair cable for NT series and exclusive cable for DV series)
Dimensions & Weight Approx. 70(W)X170(H)X153(D)mm (Expect for DV)
70(W)X210(H)X153(D)mm (DV only)
Approx. 2kg
Specifications subject to change without notice.
Back to Top
Model GD-K77DG (for NF3, R-123)
Approvals: CE
Features:
  • High brightness LED assures clear reading even in dark places
  • Trend graph for alarm evidence
  • Self-diagnostic functions
  • Two alarm levels, trouble alarm plus relay outputs
  • Maintenance capablity by remote PC
  • Various communication networks
  • CE approved
Specifications:
Model designation and signal transmission GD-K77DG: 4-20mA
GD-K77DG-NT: DC power line communication
GD-K77DG-DV: Device Net GD-K77DG-LN: Lon Works
Detection principle Pyrolysis-electronchemical cell
Target gas and detection range NF3 in air
0~30ppm
R-123 in air
0~100ppm
Gas concentration display Digital LED display, 4 digits 7 segments
Alarm display 1st alarm: Yellow LED light, 2nd alarm: Red LED light, Trouble alarm: Green LED flashing
Alarm relays Normally-open or normally-close contact for both AL1/AL2 and trouble, rated 0.25A at 125VAC/0.5A at 24VDC (Resistive load)
Self-diagnostic function Trouble, low flow, system trouble, communication error.
Operating conditions 0~40C, 30~85%RH, non-condensing
Power requirement 24VDC+10%, 10W and 100~120VAC or 200~240VAC, 70VA
Applicable tubing for outer connection O.D. 6-1t PTFE tubing (Provided with P.P coupling)
Applicable cable Shielded cable, 3C, 1.25sq. (Shielded twisted one pair cable for NT series and exclusive cable for DV series)
Dimensions & Weight Approx. GD-K77DG: 140(W)X170(H)X153(D)mm, Approx. 3.2kg
Approx. GD-K77DG-DV: 140(W)X210(H)X153(D)mm, Approx. 3.5kg
Specifications subject to change without notice.
Back to Top
Model GD-S77DG
(for TEOS,TMS,TRIMS,TMOP,HMDS )
Approvals: CE
Features:
  • High brightness LED assures clear reading even in dark places
  • Trend graph for alarm evidence
  • Self-diagnostic functions
  • Two alarm levels, trouble alarm plus relay outputs
  • Maintenance capablity by remote PC
  • Various communication networks
  • CE approved
Back to Top
Model GD-F77A (for O2 )
Approvals: CE
Features:
  • High brightness LED
  • Self-diagnostic functions
  • Two alarm levels, trouble alarm plus relay outputs
  • Various communication networks
  • CE approved
Back to Top
Model GD-K82Ai Intrinsically Safe in Japan
 
Approvals: CE, JML
Features:
  • Remote monitor capabilty by extender cable 3m
  • Remote sensor type for duct mounting available
  • Intrinsically safe design
  • Digital display(LCD) for gas concentration readout
  • Calibration and other sensor information stored in sensor memory
  • Trend graph for alarm evidence
  • Self-diagnostic functions by microprocessor
  • Quick replacement sensor
Applications:
  • Semiconductor/LCD Fabrication Plants
  • Petrochemical/ Chemical PLants
  • Iron/Steel mills
  • Work Enviroment
Back to Top
Model FP-260 AGZS
Model FP-300
Features:
  • PPB detection for many gases
  • PPB or PPM digital display
  • Easy transportability
  • Interference-free detection
  • Easy to replace cassette tape
  • Cassette tape remainder display
  • Panel mounting configuration available (FP-300)
  • Self-diagnostic functions
  • 2 alarm levels
 
 
Back to Top

CO2 Monitor

Model RI-215A
Approvals: CE
Features:
  • Easy to read LCD digital display
  • Compact, lightweight amd easy installation
  • Highly reliable Non-Disoersive Infrared gas absorption method used
  • Recording output single
  • Automatic control of ventilation in autos and buildings provides energy for energy saving
 
Back to Top

Oxygen Monitor

Model OX-500 (for O2)
Approvals: CE
Features:
  • Compact, wall mounting design
  • Highly visible 3 colour LED digital display
  • Remote sensor capabilty
  • Power cable can enter from any direction
  • Stores alarm summary data (10 alarm events, time and alarm concertration)
Specifications:
Model designation and signal transmission 4-20mA
Detection principle Galvanic cell
Target gas and detection range O2 in air 0~25%
Gas concentration display 3 digits, 3 colour LED
Alarm display Warning: Yellow LED
Alarm: Red LED
Trouble: Red error message
Alarm relays Normally-open contact for both AL1/AL2, rated 1A at 125VAC (Resistive load)
Self-diagnostic function Memory error, sensor disconnection
Operating conditions 0~40C, below 95%RH, non-condensing
Power requirement 24VDC+10% or 100~120VAC
Applicable cable 3m power cable is supplied
Structure Wall mounting
Dimensions & Weight Approx. 95(W)X135(H)X35(D)mm, Approx. 0.42kg
Specifications subject to change without notice.
Back to Top

CO Montitor

Model EC-500 Indoor carbon monoxide gas monitor
Features:
  • Compact, wall mounting design
  • Highly visible 3colour LED digital display
  • Remote sensor capablity
  • Power cable can enter from any direction
  • Stores alarm summary data. (10 alarm occurrence, time and alarm concentration)
Back to Top

For PFC, HCFC, HFC AND IPA

Model RI-257
Features:
  • wall mounting design for easy installation
  • Negliable interference from other gases
  • Self-diagnostic functions
  • 4~20mA linear outputs
  • Two alarm levels, trouble alarm plus relay outputs
  • Audible and visual alarms
  • Automatic backlight during alarm
  • Automatic zero correction function
Back to Top

N2O Monitor

Model RI-2000W (for N2O)
Features:
  • wall mounting design for easy installation
  • Negliable interference from other gases
  • Self-diagnostic functions
  • 4~20mA linear outputs
  • Two alarm levels, trouble alarm plus relay outputs
  • Audible and visual alarms
  • Automatic backlight during alarm
  • Automatic zero correction function
Specifications:
Detection principle NDIR(non-dispersive Infraed Ray Absorption) method
Target gas and detection range N2O(Nitrous oxide) 0~200ppm
Display 16 digits LCD (with backlight)
Alarm display Gas alarm: Yellow WARNING light, Red ALARM light
Trouble alarm: Flashing green light
Alarm preset level 50ppm (WARNING), 100ppm(ALARM)
Alarm relays Normally-open (standard) or normally-close(optional) contact for both WARNING/ALARM and trouble, rated 0.1mA~0.3mA at 125VAC (Resistive load)
Self-diagnostic function Lamp trouble, sensor trouble, heater trouble, low flow, fan stop, system trouble
Analog output 4~20mADC, linear, non-isolated sourcing signal, max loop load 300omega
Operating conditions 0~40C, 30~90%RH, non-condensing
Power requirement 100VAC or 220VAC +10%, 50/60Hz
Power consumption Max. 400VA
Dimensions & Weight Approx. 350(W)X440(H)X160(D)mm, Approx. 7kg
Specifications subject to change without notice.
Back to Top

Controller

Model RM-590 Series
(Multi-Channel Gas Monitoring System)
Features:
  • 4 digits digital LED display for gas concentration
  • 2 alarm levels with relay
  • User selectable alarm functions (latching, self reset), and alarm test functions
  • Integrated compact design with easy plug-in type module
  • Zero suppression function (Maintenance mode function)
  • Accepts flow failure alarm
  • Provides 4-20mA output
  • Wide variety of detectable gases and detector heads
  • LonWorks network available as option
Applications:
  • Petro-refinery, petrochemical plants
  • Chemical plants
  • Semi-conductor manufacturing plants
  • Engineering public works
  • Power station, gas utilities
  • Iron and steel works
Back to Top
Model Beacon 410 (Four Channel Wall Mount Controller)
Features:
  • Simultaneously monitor up to 4 channels
  • Digital Display of all 4 channels
  • Accepts direct connect sensors for LEL/ O2/ H2S/ CO/ CO2
  • Accepts any 4-20mA transmitter, 2 or 3 wire
  • 3 programmable alarm levels per channel
  • Up to 3 configurable alarm relays per channel
  • Zero follower automatically compensates sensor drift
  • 4-20mA analog & Modbus digital output standard
  • 115/ 220VAC or 24VAC operation
  • Audible alarm with silence feature
  • Alarm reset switch
  • Built in trouble alarm with relay
  • Weather proof NEMA 4X enclosure
  • Optional strobe & battery backup available
Applications:
  • Petrochemical plants
  • Refineries
  • Water & wastewater treatment plants
  • Pulp & paper mils
  • Gas, telephone, & eletirc utilities
  • Parking garages
  • Manufacturing facilities
  • Steel
  • Automotive
  • HVAC
Back to Top
Model RM-570A
(Multi-channel gas detection and alarm system)
Model RM-580
Features:
  • Receives a wide variety of sensors
  • Easy to read LED bargraph display (52 segments)
  • Combustible gases detectable in wide range (from PPM to %LEL) with one display unit (NC-571AW/NC-581W)
  • Accepts any 4-20 mA transmitter input powered from 24VDC
  • Two alarm levels
  • Peak hold function
  • Zero suppression function
  • Maintenance mode function
  • Alarm test mode
  • Auto zero function
  • Ability to indicate a flow failure alarm
  • 4-20mA outputs
  • Model RM-570A series features with single LED red color readout and Model RM-580 series with multi LED color readout (green, orange, red)
Applications:
  • Semiconductor Fabrication Plants
  • Petrochemical plants
  • Refineries
  • Water & wastewater treatment plants
  • Pulp & paper mils
  • Gas, telephone, & eletirc utilities
  • Iron and steel works
Back to Top

Fixed Gas Detector

Marine
Semiconductor
Oil and Gas/LPG/LNG
Others
Controllers


R K INSTRUMENTS (S) PTE LTD
102F, #03-10, Citilink Warehouse Complex,
Pasir Panjang Road, S (118530)
Tel : (65) 62753398
Fax : (65) 62753387

Email : rk@rkinstruments.com.sg
  rkqkk@singnet.com.sg