Single Channel

image of GP-146 to be place here |
Model GP-641A 
(Single -channel combustible gas detection and alarm system) |
Model GD-A8  |
Model GP-146  |
| Aproval: H.K, K.R, CCS |
Features: |
- Compact and light weight.
- Digital display(LED) for gas concentration readout.
- Self-diagnostic functions by microprocessor.
- Two alarm levels, trouble alarm
- External output 4-20mA, Relay output
- Maintenance mode function.
|
Applications: |
- LP Gas manufacturing, storage, and consuming facilities.
- Factories using high pressure gas.
- Chemical plants
- General manufacturing plants.
|
 |
 |
Model RM-630 Series 
(Single -channel gas detection and alarm system) |
Features: |
- Compact and light weight.
- Wide variety of detectable gases and detector heads
- Two alarm levels, trouble alarm
- Maintenance mode function.
- Zero suppression function
- Recorder output (option)
|
Applications: |
- Petro-refinery, petrochemical plants.
- Chemical plants
- Semiconductor manufacturing plants
- Engineering public works
- Power station, gas utilities
- Iron and steel works
- Oil/gas carriers
|
|
Model SD-705EC  |
| Approvals: TIIS |
| Features: |
|
| Specification: |
| Detection gas |
Hydrogen sulfide (H2S) in air |
| Detection principle |
Electro-chemical cell |
| Detection Range |
0-30ppm |
| Alarm preset levels |
1st: 10ppm, 2nd: 20ppm(adjustable) |
| Operating temp. & humidity |
-10C~+40C, below 95%RH (non-condensing) |
| External output |
Alarm contact: Gas alarm and trouble alarm Single output: Gas concentration 4-20mA, Linear Malfunction: 0.5mA At maintenance mode & initial clear time: 2.5mA |
| Power source |
DC24V+10% (max 2.5W) |
| Structure |
Flame proof structure Exd II BT4 |
| Signal transmission |
Max. 1.25km with CVVS 1.25sq cable Max 2km with CVVS 2.0sq cable |
| Dimensions & Weight |
205(w)X134(H)X90(D)mm, Approx. 4kg |
| Specifications subject to change without notice. |

|
|
Model Tri (3)-Head Gas Detector  |
|
| For Marine Pump room |
| Features: |
- 3 Sensors, 1 explosion proof housing
- Infrared sensors available for combustible gases
- Interfaces with Beacon 410 controller
- Available for LEL, O2, H2S and CO
- Water repellent patented sensor coating
- Long life sensors (2 + years typical)
|
| Applications: |
- Wet Wells
- Dry Wells
- Bar Screen
- Lift Station
- Digesters
- Thickeners
- Primary Clarifiers
- Pump Stations
- Confined
|
 |
Model M2 Series (Stand alone explosion proof transmitter)  |
Features: |
- Operates independent of a controller
- Direct digital readout on backlit LCD
- Available for LEL, H2O, CO and O2
- 4-20mA & digital Modbus outputs standard
- Non-intrusive calibration via magnetic wand
- 2 fully programmable alarm relays & fail relay
- H2 specific LEL version available
- Infrared combustible version available
- Patented water repellent sensor coating
- User friendly setup push buttons & LCD menus
- Intrinsically safe, CSA, C/US classified
|
Applications: |
- Petrochemical plants
- Refineries
- Offshore drilling platforms
- Water & wastewater treatment plants
- Pulp & paper mils
- Gas, telephone, & eletirc utilities
- Parking garages
- Manufacturing facilities
- Steel
- Automotive
|
 |
Model "S" Series (4-20mA Gas Sensor/Transmitter)  |
Features: |
- Explosion proof housing
- Patented water repellent sensor coating
- Operates independent of a controller
- Available for LEL, H2S, CO, O2 and ppm HC
- Long life sensors (2 + years typical)
- Competitively priced
|
Applications: |
- Petrochemical plants
- Refineries
- Offshore drilling platforms
- Water & wastewater treatment plants
- Pulp & paper mils
- Gas, telephone, & eletirc utilities
- Parking garages
- Manufacturing facilities
- Steel
- Automotive
- Chemical storage buildings
|
Semiconductor
 |
Model GD-K71D  |
Model GD-V77D  |
Model GD-F77D  |
Approvals: CE |
Features: |
- High brightness LED assures clear reading even in dark places
- Trend graph for alarm evidence
- Self-diagnostic functions
- Two alarm levels, trouble alarm plus relay outputs
- Maintenance capablity by remote PC
- Various communication networks
- CE approved
|
Specifications: |
| Model |
GD-K71D |
GD-V77D |
GD-F77D |
| Model designation and signal transmission |
GD-K71D: 4-20mA
GD-K71D-NT: DC power line communication
GD-K71D-DV: Device Net
GD-K71D-LN: Lon Works |
GD-V77D: 4-20mA
GD-V77D-NT: DC power line communication
GD-V77D-DV: Device Net
GD-V77D-LN: Lon Works |
GD-F77D: 4-20mA
GD-F77D-NT: DC power line communication
GD-F77D-DV: Device Net
GD-F77D-LN: Lon Works |
| Detection principle |
Electronchemical cell |
Semiconductor method |
Galvanic cell |
| Target gas and detection range |
Contact us for details |
H2 in air
0~2000ppm
CH2F2(R-32) in air
0~2000ppm |
O2 in air 0~25% |
| Gas concentration display |
Digital LED display, 4 digits 7 segments |
| Alarm display |
1st alarm: Yellow LED light, 2nd alarm: Red LED light, Trouble alarm: Green LED flashing |
| Alarm relays |
Normally-open or normally-close contact for both AL1/Al2 and trouble, rated 0.25A at 125VAC/0.5 at 24VDC(Resistive load) |
| Self-diagnostic function |
Trouble, low flow, system trouble, communication error. |
| Operating conditions |
0~40C, 30~85%RH, non-condensing |
0~40C, below 90%RH, non-condensing |
| Power requirement |
24VDC+10%. Approx.10W |
| Applicable tubing for outer connection |
O.D. 6-1t PTFE tubing (provided with P.P coupling) |
| Applicable cable |
Shielded cable, 3C, 1.25sq. (Shielded twisted one pair cable for NT series and exclusive cable for DV series) |
| Dimensions & Weight |
Approx. 70(W)X170(H)X153(D)mm (Expect for DV)
70(W)X210(H)X153(D)mm (DV only)
Approx. 2kg |
Specifications subject to change without notice. |
 |
Model GD-K77DG (for NF3, R-123)  |
Approvals: CE |
Features: |
- High brightness LED assures clear reading even in dark places
- Trend graph for alarm evidence
- Self-diagnostic functions
- Two alarm levels, trouble alarm plus relay outputs
- Maintenance capablity by remote PC
- Various communication networks
- CE approved
|
Specifications: |
| Model designation and signal transmission |
GD-K77DG: 4-20mA
GD-K77DG-NT: DC power line communication
GD-K77DG-DV: Device Net GD-K77DG-LN: Lon Works |
| Detection principle |
Pyrolysis-electronchemical cell |
| Target gas and detection range |
NF3 in air
0~30ppm
R-123 in air
0~100ppm |
| Gas concentration display |
Digital LED display, 4 digits 7 segments |
| Alarm display |
1st alarm: Yellow LED light, 2nd alarm: Red LED light, Trouble alarm: Green LED flashing |
| Alarm relays |
Normally-open or normally-close contact for both AL1/AL2 and trouble, rated 0.25A at 125VAC/0.5A at 24VDC (Resistive load) |
| Self-diagnostic function |
Trouble, low flow, system trouble, communication error. |
| Operating conditions |
0~40C, 30~85%RH, non-condensing |
| Power requirement |
24VDC+10%, 10W and 100~120VAC or 200~240VAC, 70VA |
| Applicable tubing for outer connection |
O.D. 6-1t PTFE tubing (Provided with P.P coupling) |
| Applicable cable |
Shielded cable, 3C, 1.25sq. (Shielded twisted one pair cable for NT series and exclusive cable for DV series) |
| Dimensions & Weight |
Approx. GD-K77DG: 140(W)X170(H)X153(D)mm, Approx. 3.2kg
Approx. GD-K77DG-DV: 140(W)X210(H)X153(D)mm, Approx. 3.5kg |
Specifications subject to change without notice. |
 |
Model GD-S77DG 
(for TEOS,TMS,TRIMS,TMOP,HMDS ) |
Approvals: CE |
Features: |
- High brightness LED assures clear reading even in dark places
- Trend graph for alarm evidence
- Self-diagnostic functions
- Two alarm levels, trouble alarm plus relay outputs
- Maintenance capablity by remote PC
- Various communication networks
- CE approved
|
 |
Model GD-F77A (for O2 )  |
Approvals: CE |
Features: |
- High brightness LED
- Self-diagnostic functions
- Two alarm levels, trouble alarm plus relay outputs
- Various communication networks
- CE approved
|
 |
Model GD-K82Ai Intrinsically Safe in Japan |
|
Approvals: CE, JML |
Features: |
- Remote monitor capabilty by extender cable 3m
- Remote sensor type for duct mounting available
- Intrinsically safe design
- Digital display(LCD) for gas concentration readout
- Calibration and other sensor information stored in sensor memory
- Trend graph for alarm evidence
- Self-diagnostic functions by microprocessor
- Quick replacement sensor
|
Applications: |
- Semiconductor/LCD Fabrication Plants
- Petrochemical/ Chemical PLants
- Iron/Steel mills
- Work Enviroment
|
 |
Model FP-260 AGZS  |
| Model FP-300 |
Features: |
- PPB detection for many gases
- PPB or PPM digital display
- Easy transportability
- Interference-free detection
- Easy to replace cassette tape
- Cassette tape remainder display
- Panel mounting configuration available (FP-300)
- Self-diagnostic functions
- 2 alarm levels
|
| |
| |
CO2 Monitor
 |
Model RI-215A  |
Approvals: CE |
Features: |
- Easy to read LCD digital display
- Compact, lightweight amd easy installation
- Highly reliable Non-Disoersive Infrared gas absorption method used
- Recording output single
- Automatic control of ventilation in autos and buildings provides energy for energy saving
|
| |
Oxygen Monitor
 |
Model OX-500 (for O2)  |
Approvals: CE |
Features: |
- Compact, wall mounting design
- Highly visible 3 colour LED digital display
- Remote sensor capabilty
- Power cable can enter from any direction
- Stores alarm summary data (10 alarm events, time and alarm concertration)
|
Specifications: |
| Model designation and signal transmission |
4-20mA
|
| Detection principle |
Galvanic cell |
| Target gas and detection range |
O2 in air 0~25% |
| Gas concentration display |
3 digits, 3 colour LED |
| Alarm display |
Warning: Yellow LED
Alarm: Red LED
Trouble: Red error message |
| Alarm relays |
Normally-open contact for both AL1/AL2, rated 1A at 125VAC (Resistive load) |
| Self-diagnostic function |
Memory error, sensor disconnection |
| Operating conditions |
0~40C, below 95%RH, non-condensing |
| Power requirement |
24VDC+10% or 100~120VAC |
| Applicable cable |
3m power cable is supplied |
| Structure |
Wall mounting |
| Dimensions & Weight |
Approx. 95(W)X135(H)X35(D)mm, Approx. 0.42kg |
Specifications subject to change without notice. |
CO Montitor
 |
Model EC-500 Indoor carbon monoxide gas monitor  |
| Features: |
- Compact, wall mounting design
- Highly visible 3colour LED digital display
- Remote sensor capablity
- Power cable can enter from any direction
- Stores alarm summary data. (10 alarm occurrence, time and alarm concentration)
|
For PFC, HCFC, HFC AND IPA
 |
Model RI-257  |
Features: |
- wall mounting design for easy installation
- Negliable interference from other gases
- Self-diagnostic functions
- 4~20mA linear outputs
- Two alarm levels, trouble alarm plus relay outputs
- Audible and visual alarms
- Automatic backlight during alarm
- Automatic zero correction function
|
N2O Monitor
 |
Model RI-2000W (for N2O)  |
Features: |
- wall mounting design for easy installation
- Negliable interference from other gases
- Self-diagnostic functions
- 4~20mA linear outputs
- Two alarm levels, trouble alarm plus relay outputs
- Audible and visual alarms
- Automatic backlight during alarm
- Automatic zero correction function
|
Specifications: |
| Detection principle |
NDIR(non-dispersive Infraed Ray Absorption) method
|
| Target gas and detection range |
N2O(Nitrous oxide) 0~200ppm |
| Display |
16 digits LCD (with backlight) |
| Alarm display |
Gas alarm: Yellow WARNING light, Red ALARM light
Trouble alarm: Flashing green light |
| Alarm preset level |
50ppm (WARNING), 100ppm(ALARM) |
| Alarm relays |
Normally-open (standard) or normally-close(optional) contact for both WARNING/ALARM and trouble, rated 0.1mA~0.3mA at 125VAC (Resistive load) |
| Self-diagnostic function |
Lamp trouble, sensor trouble, heater trouble, low flow, fan stop, system trouble |
| Analog output |
4~20mADC, linear, non-isolated sourcing signal, max loop load 300omega |
| Operating conditions |
0~40C, 30~90%RH, non-condensing |
| Power requirement |
100VAC or 220VAC +10%, 50/60Hz |
| Power consumption |
Max. 400VA |
| Dimensions & Weight |
Approx. 350(W)X440(H)X160(D)mm, Approx. 7kg |
Specifications subject to change without notice. |
Controller
 |
Model RM-590 Series 
(Multi-Channel Gas Monitoring System) |
Features: |
- 4 digits digital LED display for gas concentration
- 2 alarm levels with relay
- User selectable alarm functions (latching, self reset), and alarm test functions
- Integrated compact design with easy plug-in type module
- Zero suppression function (Maintenance mode function)
- Accepts flow failure alarm
- Provides 4-20mA output
- Wide variety of detectable gases and detector heads
- LonWorks network available as option
|
Applications: |
- Petro-refinery, petrochemical plants
- Chemical plants
- Semi-conductor manufacturing plants
- Engineering public works
- Power station, gas utilities
- Iron and steel works
|
 |
Model Beacon 410 (Four Channel Wall Mount Controller)  |
Features: |
- Simultaneously monitor up to 4 channels
- Digital Display of all 4 channels
- Accepts direct connect sensors for LEL/ O2/ H2S/ CO/ CO2
- Accepts any 4-20mA transmitter, 2 or 3 wire
- 3 programmable alarm levels per channel
- Up to 3 configurable alarm relays per channel
- Zero follower automatically compensates sensor drift
- 4-20mA analog & Modbus digital output standard
- 115/ 220VAC or 24VAC operation
- Audible alarm with silence feature
- Alarm reset switch
- Built in trouble alarm with relay
- Weather proof NEMA 4X enclosure
- Optional strobe & battery backup available
|
Applications: |
- Petrochemical plants
- Refineries
- Water & wastewater treatment plants
- Pulp & paper mils
- Gas, telephone, & eletirc utilities
- Parking garages
- Manufacturing facilities
- Steel
- Automotive
- HVAC
|
 |
Model RM-570A 
(Multi-channel gas detection and alarm system) |
Model RM-580 |
Features: |
- Receives a wide variety of sensors
- Easy to read LED bargraph display (52 segments)
- Combustible gases detectable in wide range (from PPM to %LEL) with one display unit (NC-571AW/NC-581W)
- Accepts any 4-20 mA transmitter input powered from 24VDC
- Two alarm levels
- Peak hold function
- Zero suppression function
- Maintenance mode function
- Alarm test mode
- Auto zero function
- Ability to indicate a flow failure alarm
- 4-20mA outputs
- Model RM-570A series features with single LED red color readout and Model RM-580 series with multi LED color readout (green, orange, red)
|
Applications: |
- Semiconductor Fabrication Plants
- Petrochemical plants
- Refineries
- Water & wastewater treatment plants
- Pulp & paper mils
- Gas, telephone, & eletirc utilities
- Iron and steel works
|
|
Fixed Gas Detector
R K INSTRUMENTS (S) PTE LTD
102F, #03-10, Citilink Warehouse Complex,
Pasir Panjang Road, S (118530)
Tel : (65) 62753398
Fax : (65) 62753387
|